Description
Approvals
DNV – GL, BV, LLOYD’S, ABS, NKK, KR, MED
Applicable Specifications
EXCEED SAE 100R15 – ISO 3862
Biological oils compatibility. Exceed EN standard. Impulse tested up to 1.000.000 impulse cycles.
Internal hose: Synthetic rubber, extruded whole without joints, of uniform thickness.
Reinforcement: 4 high tensile steel wire spiral up to size 1”, 6 spiral from size 1,1/4.
Covering: Abrasion resistant synthetic rubber resistant to oils, fuels, atmospheric conditions. MSHA.
Recommended fluids: Mineral and biological oils, glicol-water based, water, lubricants, compressed air
Operating temperature: : from -40 to + 121° C (Intermittent 125°C)
Part Number | ID | OD | Max WP | Min BP | Min BR | Weight | Ferrule | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
in | mm | mm | bar | psi | bar | psi | mm | inch | kg/m | lb/ft | |||
TFDR015-10 | 5/8” | 16.0 | 26.8 | 420 | 6090 | 1750 | 25375 | 150 | 5.901 | 0.705 | 0.474 | 0013-10/X Series | |
TFDR015-12 | 3/4” | 19.0 | 32.0 | 420 | 6090 | 1750 | 25375 | 210 | 8.268 | 1.573 | 1.057 | 004N-12/X Series | |
TFDR015-16 | 1“ | 25.4 | 38.7 | 420 | 6090 | 1700 | 24650 | 240 | 9.449 | 2.116 | 1.422 | 0013-16/X Series | |
TFDR015-20 | 1.1/4” | 31.8 | 49.7 | 420 | 6090 | 1680 | 24360 | 265 | 10.433 | 3.891 | 2.615 | 0013-20/X Series | |
TFDR015-24 | 1.1/2” | 38.1 | 57.8 | 420 | 6090 | 1680 | 24360 | 310 | 12.205 | 5.182 | 3.482 | 0013-24/X Series | |
TFDR015-32 | 2“ | 50.8 | 72.0 | 420 | 6090 | 1680 | 24360 | 590 | 23.228 | 6.892 | 4.631 | 0013-32/X Series |